FTIR-ATR
.png)
Overview
Product Overview
The KFTIR-5200R-TA Advanced Fourier Transform Infrared Spectrometer is a high-performance analytical system designed for accurate qualitative and quantitative characterization of a wide range of materials. Combining both Transmission and Monolithic Diamond ATR capabilities in a single platform, the instrument provides exceptional flexibility for routine laboratory analysis and advanced research applications.
Engineered with a high-throughput optical architecture, dynamic alignment Michelson interferometer, advanced electronics, and intelligent diagnostics, the KFTIR-5200R-TA delivers highly reliable, reproducible, and high-quality infrared spectra. Its sealed and desiccated optical system ensures long-term stability while minimizing maintenance requirements and maximizing operational reliability.
The integrated Transmission and Diamond ATR configurations enable rapid analysis of solids, liquids, powders, gels, films, polymers, pharmaceuticals, chemicals, and research samples with minimal sample preparation. The monolithic diamond ATR crystal offers excellent chemical resistance and durability, making it suitable for demanding analytical environments.
Equipped with advanced spectral processing software, library search functionality, workflow automation tools, quantitative analysis capabilities, and real-time system diagnostics, the instrument provides efficient data acquisition and comprehensive analytical performance for modern laboratories.
Designed for versatility, the KFTIR-5200R-TA is widely used in pharmaceutical analysis, chemical characterization, polymer and plastics research, petrochemical investigations, forensic science, environmental monitoring, quality control laboratories, and academic research institutions.
Overall, the KFTIR-5200R-TA Advanced FTIR Spectrometer offers a powerful and future-ready solution for material characterization, combining superior optical performance, dual sampling flexibility, intelligent automation, and reliable analytical results for a broad range of scientific and industrial applications.
Key Features
- Dual analysis configuration combining Transmission and Monolithic Diamond ATR capabilities in a single instrument.
- High-throughput optical system designed for superior sensitivity, accuracy, and analytical performance.
- Wide spectral range of 8000–350 cm⁻¹ for comprehensive material characterization.
- Dynamic alignment Michelson interferometer ensuring long-term optical stability and measurement reliability.
- Monolithic diamond ATR crystal for rapid analysis of solids, liquids, powders, gels, films, and polymers.
- Excellent chemical resistance and durability for demanding laboratory applications.
- High signal-to-noise performance enabling accurate detection of low-level absorbance features.
- Superior spectral resolution for precise peak separation and detailed molecular characterization.
- Advanced spectral processing software with library search and automated workflow functionality.
- Comprehensive qualitative and quantitative analysis capabilities for routine and research applications.
- Sealed and desiccated optical system for enhanced stability and reduced maintenance requirements.
- Long-life high-energy infrared source for consistent analytical performance.
- Multiple detector options supporting high sensitivity and broad analytical flexibility.
- Real-time instrument status indication for improved operational control and reliability.
- USB and Ethernet connectivity for seamless data transfer and network integration.
- Upgradeable architecture supporting additional accessories and advanced analytical modules.
- Minimal sample preparation requirements through integrated Diamond ATR technology.
- Suitable for pharmaceuticals, chemicals, polymers, petrochemicals, forensics, environmental analysis, and academic research.
- Compact and robust design engineered for routine quality control and advanced laboratory applications.
Specifications
| Parameter | Value |
|---|---|
| Instrument Type | Advanced Fourier Transform Infrared (FTIR) Spectrometer |
| Model | KFTIR-5200R-TA |
| Configuration | Transmission + Diamond ATR Configuration |
| Measurement Technique | Fourier Transform Infrared Spectroscopy (FTIR) |
| Spectral Range | 8000 – 350 cm⁻¹ |
| Resolution | Better than 0.6 cm⁻¹ |
| Wavenumber Accuracy | 0.05 cm⁻¹ at 2000 cm⁻¹ |
| Wavenumber Precision | 0.001 cm⁻¹ at 2000 cm⁻¹ |
| Signal-to-Noise Ratio | 33000:1 |
| Interferometer | Dynamic Alignment Michelson Interferometer |
| Beam Splitter | KBr / Ge |
| Infrared Source | Long-Life High-Energy IR Source |
| Detector Options | DTGS / DLaTGS |
| Sampling Modes | Transmission & Diamond ATR |
| ATR Crystal | Monolithic Diamond |
| Transmission Analysis | Suitable for liquids, films, KBr pellets, and transmission accessories |
| ATR Analysis | Suitable for solids, powders, liquids, gels, films, and polymers with minimal sample preparation |
| Optical System | High-throughput optical architecture for enhanced sensitivity and energy transmission |
| Diagnostic System | Intelligent real-time monitoring of critical instrument parameters |
| Software Functions | Advanced spectral processing, library search, workflow automation, quantitative analysis, and data management |
| Connectivity | USB & Ethernet |
| Status Monitoring | Real-time instrument and performance status indication |
| Upgrade Capability | Upgradeable architecture supporting additional accessories and advanced analytical modules |
| Power Supply | 100–240 VAC, 50/60 Hz |
| System Design | Sealed and desiccated optical system for long-term stability and low maintenance |
| Applications | Pharmaceuticals, Chemicals, Polymers & Plastics, Petrochemicals, Forensic Science, Environmental Analysis, Academic Research, Quality Control, and Material Characterization |
| Suitable Sample Types | Solids, Liquids, Powders, Gels, Films, Polymers, Chemicals, Pharmaceutical Samples, and Research Materials |
Request a Quotation
Interested in this product? Fill out the form below and our team will get back to you with pricing and availability.